Sports centre Turó De La Peira

Thermodynamic and day-lighting simulation of the Turó de la Peira Indoor Swimming Pool and Sports Centre in Barcelona city. The 3,900 m2 building includes a heated pool and multi-sports hall, built with a cross-laminated timber structure.

Project nZEB

Sports centre Turó De La Peira

Description

Thermodynamic and day-lighting simulation of the Turó de la Peira Indoor Swimming Pool and Sports Centre in Barcelona city. The 3,900 m2 building includes a heated pool and multi-sports hall, built with a cross-laminated timber structure. The project won the WAF (World Architecture Festival) 2019 category for Sports, and was High Commended in the Category “Use of Certified Timber”. The thermo-dynamic simulations focused on reducing the heating and cooling demands of the building, optimising daylighting and thermal comfort and reducing the environmental impact of the building. The optimization of the thermal envelope created savings of 182,011 kWh/a, approximately € 27,302/a. A 100 % passive heating, cooling and ventilation solution was developed for the multi-sports hall.

Year: 2015

Location: Barcelona

Services:
Thermodynamic and daylighting simulation

LILAC

Energy consultancy for the LILAC housing cooperative in Leeds, UK, a 20-home development built with the ModCell prefabricated timber system with straw insulation.

Project nZEB

LILAC

Description

Energy consultancy for the LILAC housing cooperative in Leeds, UK, a 20-home development built with the ModCell prefabricated timber system with straw insulation.

The energy consultancy included a comparative study, energy strategy and outline design of thermal and electrical services, including a dynamic simulation study of the buildings using DesignBuilder-EnergyPlus to determine heating loads and summer comfort. The technologies studied included gas boilers, solar thermal, photovoltaic, geothermal, biomass and a hybrid PV-solar thermal-heat pump system.

Year: 2011

Location: Leeds, UK

Services:
Energy consultancy

Larixhaus

Passivhaus consultancy and M & E engineering design for a single-family home, certified Passivhaus Classic, built with renewable bio-based materials in a prefabricated timber system with straw insulation.

Project Passivhaus, nZEB and M & E engineering

Larixhaus

Description

Passivhaus consultancy and M & E engineering design for a single-family home, certified Passivhaus Classic, built with renewable bio-based materials in a prefabricated timber system with straw insulation.

Passivhaus consultancy included PHPP energy simulation and performance optimisation, thermal envelope design, strategies to combat summer overheating and thermal bridge calculations. HVAC design included an air-source heat pump for DHW production. Heating system with electric radiators and a wood-burning stove, Ventilation with ducted mechanical ventilation with heat recovery. Passive cooling with natural night ventilation and external shading devices.

Year: 2015

Location: Collsuspina, Moianès

Services:
Passivhaus consultancy, M & E engineering

Can Tanca

Passivhaus consultancy and M & E engineering design for a single-family off-grid home, certified Passivhaus Premium and BREEAM, and built with renewable bio-based materials, including a lightweight timber frame structure and wood fibre insulation.

Proyect Passivhaus, nZEB, Renewable energy and M & E engineering

Can Tanca

Description

Passivhaus consultancy and M & E engineering design for a single-family off-grid home, certified Passivhaus Premium and BREEAM, and built with renewable bio-based materials, including a lightweight timber frame structure and wood fibre insulation.

Passivhaus consultancy included PHPP energy simulation and performance optimisation, thermal envelope design, strategies to combat summer overheating and thermal bridge calculations.

HVAC design included an air-source heat pump for heating, cooling and DHW production, ducted mechanical ventilation with heat recovery, and a dehumidifier/cooling and heating cool with radiant ceiling panels. All services were integrated and controlled with the Loxone home automation system, providing extensive monitoring and preventative maintenance capability. An on-site solar photovoltaic installation and battery system means the home is entirely energy self-sufficient, with no grid connection. The home also has a rainwater collection and grey water treatment system, with no mains water connection.

Year: 2016

Location: St. Llorenç de Balàfia, Ibiza

Services:
Passivhaus consultancy, M & E engineering

Carrer Nou

Passivhaus consultancy for the retrofit of a multi-family terraced building in the city centre of Girona, achieving Passivhaus EnerPHit certification. The building houses 5 apartments over 6 floors. Winner of the Grand Prize of Sustainable Renovation, of the Green Solutions Awards 2018, Construction21 Spain.

Project Passivhaus, nZEB, M & E engineering

Carrer Nou

Description

Passivhaus consultancy for the retrofit of a multi-family terraced building in the city centre of Girona, achieving Passivhaus EnerPHit certification. The building houses 5 apartments over 6 floors. Winner of the Grand Prize of Sustainable Renovation, of the Green Solutions Awards 2018, Construction21 Spain.

Passivhaus consultancy included PHPP energy simulation and performance optimisation, thermal envelope design, strategies to combat summer overheating, thermal bridge calculations, and dynamic hygrothermal simulation with WUFI for the analysis of interstitial condensation risk and prevention of moisture damage. Progetic designed the control system to integrate radiant ceiling heating, cooling, and dehumidification systems, together with heat recovery ventilation, with the Loxone home automation system.

Year: 2017

Location: Girona

Services:
Passivhaus consultancy, M & E engineering, dynamic hygrothermal modelling